The potassium ion in the drilling fluid aims to stabilize shale and restrain the clay’s dilatability. So, the potassium ion content must be measured accurately so as to control the performances of drilling fluid. SY-2 hand operated centrifuge is used to measure the potassium ion content in the drilling fluid whose potassium ion content is more than 5000mg/l or KCl concentration is bigger than 3.5lb/bbl. Use the perchloride to deposit the potassium ion in the centrifuge, then determine the volume of the deposit, and numerate the content from the criterion curve.
Digital PH meter model PHS-3C is a high-precision instrument for measuring PH of aqueous solution in laboratory. It is mainly composed of main engine, composite electrode, bracket and power supply, etc. This instrument has PH and MV two functions, adopts E201 composite electrode with fast reaction and good stability features.
Hand Operated Centrifuge Model SY-2 - The potassium ion in the drilling fluid aims to stabilize shale and restrain the clay’s dilatability. So, the potassium ion content must be measured accurately so as to control the performances of drilling fluid.
Hand Operated Centrifuge Model SY-5 - The potassium ion in the drilling fluid aims to stabilize shale and restrain the clay’s dilatability. Therefore the potassium ion content must be measured accurately so as to control the performances of drilling fluid.
Garrett gas train test is used to determine the content of soluble sulfide in drilling fluid. The instrument is mainly composed of a row of transparent plastic chambers, an inert gas source, a pressure regulator, a floating ball flowmeter and a disperser.
Field test kits are used in drilling fluid analysis laboratories or drilling field services for a variety of chemical analysis. The box is flexible and easy to carry, and can be widely used in oil fields, chemical laboratories and professional colleges.
The potassium ion in the drilling fluid aims to stabilize shale and restrain the clay's dilatability. So, the potassium ion content must be measured accurately so as to control the performances of drilling fluid.
Hand operated centrifuge is used to measure potassium ion content of drilling fluid when potassium ion concentration is higher than 5000mg/1 or KC1 concentration is higher than 3.5lb/bbl. After using perchlorate to precipitate potassium ion in centrifuge tube, measure the precipitation volume, the standard curve will show potassium ion content.
(Garrett Gas Train Test Model QTH) MODEL QTH Garrett Gas Train Kit contains the essential equipment and reagents for measuring sulfides and carbonates by the Garrett Gas Train method. This procedure follows API Recommended Practices.